12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 369
Interactive Command Set
CONNECTION FACTORY
Use this command to restore the current connection
configuration in the Communications module.
Level 4
Same as Level 3 operation
Remarks
This command provides a way for the unit to save default settings
that the user prefers for operation. The target module restores user
defaults in the event that current nonvolatile RAM information in
the target module is lost.
If user information is not present, or unusable, the target module
restores the current factory settings. If the factory settings are also
not usable, the software initializes non-volatile RAM with the
current program defaults and transfers those setting into
non-volatile RAM as the new factory settings.
Related
Restrictions None
Note:
Restore the user list to factory settings by using the
USER
INITUSERTABLE
command.