12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 245
Alarm Messages
Table A-2. Communications Module Alarm Messages
Alarm
Description
Alarm
Number
Default
Alarm
Level
Status
Messages
Description/
Corrective Action
Module-to-module
communication
0
Minor
Ok
Bad
Unable to communicate
with other modules.
Re-seat modules.
Indication of output
controller
mastership
1
Minor
Ok
Bad
Identifies master output
controller. No action
necessary.
Status of Power A
2
Minor
Ok
Lost
Verify that the fuse for
Power A is properly
installed and not OPEN.
Verify that Power Bus A is
providing –48 vDC to the
unit. If no power is
connected to the Power A
input and there is no plan to
connect power, issue the
command
AL 10-1 IG
at
the prompt.
Status of Power B
3
Minor
Ok
Lost
Verify that the fuse for
Power B is properly
installed and not OPEN.
Verify that Power Bus B
is providing –48 vDC to
the unit. If no power is
connected to the Power
B input and there is no
plan to connect power,
enter the command
AL
10-1 IG
at the prompt.
Status of module’s
serial peripheral
interface hardware
(SPI watchdog
timeout)
4
Minor
Ok
Timeout
Unable to communicate
with other modules.
Re-seat module.
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...