Installing the SSU-2000
After Turn Up
86
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Communications Module
– The POWER LED turns green when power is applied
to the unit and stays green. The STATUS LED blinks green and amber for
approximately 10 to 15 seconds and then stays green. The -48V POWER LEDs
A and B turn green to indicate that the power supplies are connected. If one of
these LEDs are amber, the polarity of that power connection is reversed and
needs to be switched. The three ALARM LEDs clear after ~1 minute. After
initialization, if there are any alarms, it takes approximately 30 seconds to
register and the ALARM LED turns amber. The ETHERNET LINK LED blinks
green for approximately 30 seconds and stays green.
Input Module
– The POWER LED turns green when power is applied to the unit
and remains green while the system is powered up. The STATUS LED blinks
green and amber for approximately 10 to 15 seconds and then stays green. The
PORT 1 REF LED blinks for approximately 5 to 10 seconds and turns green for
the reference input and off for the others. The INPUT LED blinks for
approximately 5 to 10 seconds and turns green for every valid input or amber for
not valid inputs.
Output Module
– The POWER LED turns green when power is applied to the unit
and stays green. The STATUS LED blinks green and amber for approximately 10
to 15 seconds and then stays green. The SOURCE LED turns green for the
source clock, amber for an enabled clock that is not present and off for an
enabled clock that is present but not the source clock.
After Turn Up
This completes the turn-up procedures. After completing the turn-up procedures
perform the following:
Assign a System Administrator and any additional users to the system using the
procedures in
Adding An Administrator-Level User to the System
Make any required changes to the factory default configuration settings as
described in
Complete the commissioning tests in
, to ensure that
the system is functioning properly.
Chapter 5, Maintenance and Troubleshooting
,
to clear any system
alarms that might occur.
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...