RTRV-PRMTR-CCOUT:[tid]:[aid]:
ctag;
Valid aid code:
ALL
,
SxAy[-z]
This command returns the settings for the composite clock
port designated by the
aid
. If a port is specified in the
request, the format for each response message line is:
^^^"aid:mode,level,bypass,pstate,duty,pcomp"<cr lf>
where:
aid
= port access identifier
mode
= CC
(composite clock)
level
= minimum clock level to enable outputs on the
module [WARM|ACQ|LOCK]
bypass
= allows Clock C selection: [ON|OFF]
pstate
= port state [ON|OFF]
duty
= duty cycle of the modules outputs [1|0] where 1 =
5/8 and 0 = 50/50
pcomp
= phase compensation [1 through 7]
When no port is specified by the
aid
, then the response is
four lines as follows:
^^^"aid: mode,level,bypass"<cr lf>
^^^"aid:pstate1,pstate2,pstate3,…pstate20”<cr lf>
^^^"aid:duty1,duty2,duty3,…duty20”<cr lf>
^^^"aid:pcomp1,pcomp2,pcomp3,…,pcomp20”<cr lf>
Line 1 contains:
aid
= module access identifier
mode
= CC
level
= minimum clock level to enable outputs on the
module [WARM|ACQ|LOCK]
bypass
= allow Clock C selection: [ON|OFF]
Line 2 contains:
aid = module access identifier
pstate#
port state [1| 0] (1 = ON, 0 = OFF), where # =
port number 1 through 20
Line 3 contains:
aid
= module access identifier
duty#
= duty cycle of the module outputs [1|0], where: 1
= 5/8, 0 = 50/50
#
= port number 1 through 20
Line 4 contains:
aid
= module access identifier
pcomp#
= phase compensation 1 through 7
#
= port number 1 through 20
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...