Shelf Module Slot Addressing and Size Assignments
418
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Shelf Module Slot Addressing and Size Assignments
outlines the shelf module slot addressing and size assignments.
I/O Connector Grounding
outlines I/O connector grounding for all connectors.
Table D-8. Shelf Module Slot Addressing and Size Assignments
Slot-A
Address
Module Types
Comments
1
1
Clock
Clock A
2
2
Com
Communications
3
3
I/O or Receiver
Input, non-redundant Output, or a GPS
Receiver module
4
4
I/O, Output Pair A
Input or Output, paired with 5
5
5
I/O, Output Pair A or Receiver
Input, Output, paired with 4, or a GPS
Receiver module
6, 7
6, 7
I/O, Output Pair B
Inputs or paired Output modules
8, 9
8, 9
I/O, Output Pair C
Inputs or paired Output modules
10, 11
10, 11
I/O, Output Pair D
Inputs or paired Outputs modules
12 - 15
I/O, Extras
Reserved for future I/O
12
17
Clock
Clock B
0
All
Addresses all modules in the Shelf
Table D-9. I/O Connector Grounding
Name
Connector
Type
Reference
Description
Termination Type
Local OSC A
BNC
J1
Body/Shield: Connected to Frame Ground Plane
Local OSC B
BNC
J2
Body/Shield: Connected to Frame Ground Plane
Ethernet
10-Base-T
RJ45
J3
Body/Shield: Connected to Frame Ground Plane
Serial Port A
DE9S
J4
Body/Shield: Connected to Frame Ground Plane
Serial Port B
DE9S
J5
Body/Shield: Connected to Frame Ground Plane
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...