Input Module Reference Data
Input Adapter Panels
168
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Factory Default (Basic) Configuration
The configuration settings for the Composite Clock Input module are listed in
Input Adapter Panels
This section describes the input adapters available to connect typical
telecommunications signals to the rear panel of the SSU-2000 and SDU-2000.
Input Adapter Panel for 1-Port Input Module
Symmetricom offers three Input Adapter panels for use with 1-port Input modules.
Each panel has the following common features:
Accommodates up to four separate input signals
Switch-selected inputs allow for DE9 and another connector type
Switchable input termination impedance
Switch-selected link between signal and frame ground (when a frame ground is
connected to the lug on the rear panel)
1-m SCSI connection cable is included with the Adapter
The Input Adapter (part number 22013069-001-0) used with a 1-Port Input module
is shown in
. Each port has a switch-selected BNC and a DE9 connector,
and the input termination impedance is switch-selectable between 50, 75, 100, 120,
or 2.2 k
Ω
.
Table 7-12. Composite Clock Input Module Configuration Settings
Configuration Setting
Factory Default
Range
Provisioned PQL
4
1 – 16
Priority
0
1 – 10 (0 = Monitor)
Input Signal Error Limit
LOS = 1, BPV = 1
LOS: 1 – 100
BPV: 1 – 100000
Input Signal Clear Limit
LOS = 5, BPV = 5
LOS: 1 – 100
BPV: 1 – 100000
Alarm Elevation Time
86400 seconds
0 – 500000 seconds
Port Status
Enabled
Enabled/Disabled
Port Name
None (blank)
Any string from 0 – 20 characters
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...