Alarm Messages
246
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Table A-3. Input Module Alarm Messages
Alarm
Description
Alarm
Number
Default
Alarm
Level
Status
Messages
Description/
Corrective Action
DS1/E1 Input Module Alarms
Loss of signal fault
status
0
Minor
Ok
Active
Verify signal is
connected. To extinguish,
disable port.
Alarm indication
signal fault status
1
Minor
Ok
Active
Verify input signal is
good. Port can be
disabled.
Out of frame signal
fault status
2
Minor
Ok
Active
Change frame type:
DS1-ESF or D4
E1-CAS or CCS
Bipolar violation
signal fault status
3
Minor
Ok
Active
Verify port ZS is on.
Verify signal is good.
CRC error fault
status
4
Minor
Ok
Active
Verify port CRC is off.
Verify signal is good.
MTIE fault status
limit 1
5
Minor
Ok
Exceeded
MTIE limit 1 has been
exceeded.
MTIE fault status
limit 2
6
Minor
Ok
Exceeded
MTIE limit 2 has been
exceeded.
Received PQL
below provisioned
PQL status
7
Minor
Ok
Below Prov
Received SSM (PQL) is
below provisioned PQL.
No SSM status
8
Minor
Ok
Lost
Set port SSM to Off to
clear.
Module boot
problem
9
Minor
Ok
Failed
Re-seat module.
Clock PLL not
locked
10
Minor
Ok
Not Locked
Re-seat module.
Input PLL not
locked
11
Minor
Ok
Not Locked
Verify input frequency
setting. Re-seat module.
Phase measurement
hardware fault
12
Minor
Ok
Bad
Re-seat module.
Frequency
measurement
range exceeded
13
Minor
Ok
Exceeded
Input frequency greater
than threshold. Monitor
frequency; if persistent,
check source.
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...