Composite Clock Output Module Default Settings
430
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Composite Clock Output Module Default Settings
The Composite Clock Output module maintains factory default and current user
configuration settings. The configuration settings for the Composite Clock Output
Module are provided in
RS-422 Output Module Default Settings
The factory default setting and range for all RS-422 Output module software
parameters are listed in
Table E-12. Composite Clock Output Module Configuration
Configuration Setting
Factory Default
Range
Port State
Disabled
Disabled/Enabled
Min Clock
Acquire
Acquire/Lock
Framing
Not applicable
Not applicable
Zero Suppression
Not applicable
Not applicable
CRC
Not applicable
Not applicable
SSM
Not applicable
Not applicable
PQL
4
Not applicable
Bypass
On
On/Off
Fault Action
On
Off/On/Auto
Duty Cycle
5/8
5/8 or 50/50
Table E-13. RS-422 Output Module Configuration
Configuration Setting
Factory Default
Range
Port State
Disabled
Disabled/Enabled
Min Clock
Acquire
Acquire/Lock
Framing
Not applicable
Not applicable
Bypass
On
On/Off
Fault Action
On
Off/On/Auto
Duty Cycle
50/50
5/8 or 50/50
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...