Interactive Command Set
350
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
LRM
Use this command to display the Line Retiming Unit status and settings.
Level 0
Not applicable
Level 1:
LRM [xAy]
Level 2:
Same as level 1 operation.
Level 3:
Same as Level 2 operation, with the following additions. Use this
command to change the settings of the specified LRM module.
LRM xAy-z[&&z] {ENABLE|DISABLE}
LRM xAy-z[&&z] LBO {133FT|266FT|399FT|533FT|655FT}
LRM xAy-z[&&z] SLIP {CLR|threshold_count}
LRM xAy-z[&&z] BPV {CLR}
LRM xAy-z[&&z] CID {CLR|"circuit_id"}
LRM xAy-z FLT {SQUELCH|AIS}
Options are:
ENABLE/DISABLEEnable/Disable LRM ports
LBO
Line Built-Out
SLIP
Clear SLIP accumulation counter or set 24 hour slip
threshold count
BPV
Clear BPV accumulation counter
CID
Clear or Set Circuit ID
FLT
Defines side 1 output generation when the LRU has a
loss of signal on side 1 input, loss of all reference
sources (PLL unlock), or if the input signal’s frequency
has exceeded the LRU’s ability to retime data. The
FAULT strategy can be provisioned to AIS or Squelch.
Level 4:
Same as level 3 operation
Related:
,
Fault
CTA Installed
CTA Not Installed
Side 1 LOS
FAULT
STRATEGY
FAULT
STRATEGY
PLL Unlock
CTA Engaged
FAULT
STRATEGY
Excessive Input
Frequency
FAULT
STRATEGY
FAULT
STRATEGY
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...