12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 297
TL1 Command Interface
RTRV-PRMTR-OUTE12048:[tid]:
[aid]:ctag;
Valid aid code:
ALL
,
SxA[y[-z]]
This command returns the settings for the port specified by
the aid. The format for each response message line is:
^^^"aid:mode,bypass,zs,signal,pstate, squelch"
<cr lf>
where:
aid
= aid for the module
mode
= CAS
bypass
= [ON|OFF] for allowing Clock C selection
zs
(zero suppression) = [ON|OFF]
signal
= port signal type [E1|2048]
pstate
= port enabled state [ON|OFF
squelch
= PQL threshold value [0|1|2|...|16]; when a
reference clock PQL value exceeds this threshold, then
the port output is disabled. Zero indicates the function is
disabled.
When the aid does not specify a port, the response is:
^^^"aid:mode,bypass,zs"<cr lf>
^^^"aid:signal1,signal2,...signal20"<cr lf>
^^^"aid:pstate1,pstate2,...pstate20"<cr lf>
^^^"aid:squelch1,squelch2,...squelch20" <cr lf>
where:
Line 1 contains:
aid
= aid for the module
mode
= CAS
bypass
= [ON|OFF] for allowing Clock C selection
zs
= zero suppression: [OFF|ON]
Line 2 contains:
aid
= aid for the module
signal#
= signal type [0|1] (0 is 2048, 1 is E1) and
#
is
the port number 1 through 20
Line 3 contains:
aid
= aid for the module
pstate#
= port enabled state [0|1] (0 is Off, 1 is On) and
#
is the port number 1 through 20
Line 4 contains:
aid
= aid for the module
squelch#
= squelch value [0|1|...|16] and
#
is the port
number 1 through 20
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...