12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 167
Input Module Reference Data
Composite Clock Input Module
Status LED Indicators
The CC Input module is equipped with four status LEDs as shown in
. The
LED status assignments are described in
.
Figure 7-8.
Front Panel of the Composite Clock Input Module
Table 7-11. Composite Clock Input Module Status LED Indicators
Indicator
Color
Description
POWER
Green
On = The module is rec5 vDC
STATUS
Green/Amber
Green = Unit is in Normal mode of operation; no faults
Amber = Fault condition detected
Blinking = Disabled or firmware upgrade in progress
REF
Green
On = Selected as the input reference
Off = Not selected as input reference
INPUT
Green/Amber
On (Green) = Valid reference is connected
On (Amber) = Internal port fault
Blinking (Amber) = External port fault (LOS, BPV density)