12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide
43
Product Overview
SSU-2000 Family of Modules
Some of the common module features include:
Any module can be inserted or removed while power is applied without affecting
the operation of other modules in the system.
All modules are individually fused to protect the system in case of a short circuit
on any one module.
All modules have front panel status LEDs.
All modules are equipped with ejector tabs for ease of installation and removal
and secured in place with captured screws to provide module security and
reduce the occurrence of unauthorized removal.
All SSU-2000 modules have an integrated CPU with firmware and are software
configurable.
Each module slot also has three pins connected together on its assigned Hybrid
DIN connector which permits the system to detect when a particular module is
removed. More information is available for each of these modules in
.
Clock and Communications Modules
Stratum 2E Clock Module
The Stratum 2E Clock module uses a Rubidium oscillator and meets the
requirements of ANSI and Telcordia Industries (Bellcore) for Stratum 2 clocks. This
clock also meets the ITU-T and ETSI specifications for Type II Transit Node clocks.
The module reads measurement data from the input modules, provide frequency
control of its oscillator through DDS circuitry, and generates a reference signal used
by the input and output modules. The clock module also maintains phase
synchronization with the redundant clock module. For more information, see
Stratum 3E Clock Module
The Stratum 3E Clock module meets or exceeds performance requirements for
ANSI and Bellcore Stratum 3E and ITU and ETSI Type III Local Node clocks.
The Stratum 3E Clock Module reads measurement data from the Input modules,
provide frequency control of the oscillators through DDS circuitry, and generates a
reference signal used by the Input and Output modules. The Clock module
maintains phase synchronization with the redundant Clock module. Its hardware
and software also provides for temperature compensation, aging compensation for
quartz oscillators, an initial offset adjustment, and frequency adjustment resolution
of 1 x 10
-13
or better. For more information, see
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...