12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 247
Alarm Messages
Hardware
configuration fault
14
Major
Ok
Failed
Call Symmetricom Global
Services. Return to
factory.
GPS Input Module Alarms
Hardware
configuration fault
0
Major
Ok
Failed
Call Symmetricom Global
Services. Return to
factory.
GPS Engine
tracking status
1
Minor
Ok
Not Tracking
No visible satellites seen
at startup.
Antenna
connection status
2
Minor
Ok
Not Connected
Verify that:
The antenna is
connected
The cable and
connectors are not
damaged
The antenna is placed
correctly
Antenna condition
fault
3
Minor
Ok
Shorted
Ring out the cable to
ensure that the center
conductor is not shorted
to the sleeve, then verify
that:
The antenna cable is
connected properly
The cable and
connectors are not
damaged
GPS Engine
hardware fault
4
Minor
Ok
Bad
Reseat module. If
problem persists, call
Symmetricom Global
Services.
Engine system fault
5
Minor
Ok
Bad
If alarm doesn’t clear
after 30 minutes, call
Symmetricom Global
Services.
Position unknown
fault
6
Minor
Ok
Unknown
If alarm doesn’t clear
after 1 hour, call
Symmetricom Global
Services.
Table A-3. Input Module Alarm Messages (Continued)
Alarm
Description
Alarm
Number
Default
Alarm
Level
Status
Messages
Description/
Corrective Action
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...