12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 437
SSU-2000 Shelf Specifications
Communications Ports
Three EIA-232 Serial Ports:
Serial PORT-A (J4)
Serial PORT-B (J5)
Comms Module Serial Port
One Ethernet Port
Ethernet port (10 Base T)
Communication Management
Management Interface
Simple fault, visual and contact closures
ICS
TL1
SNMP
Input Section
Ports
Maximum of 27; 1 or 3 ports per Input module
Reference or monitoring capability
Signal Type
DS1, E1, 2048 kHz (G.703 Sec.13), 1.544 MHz, 2.048 MHz, 1, 5,
and 10 MHz Clocks (user-settable)
GPS
Integrated (single or dual)
Sync Status Messaging (SSM)
Fully supported
Selection Mode
Priority and PQL (user settable)
Performance Measurement
Resolution
1 ns
Sampling Rate
40 Hz
MTIE and TDEV
Exceeds latest ANSI, ITU-T and Telcordia Technologies
standards
Clock
Type (Holdover)
Stratum 2E Rubidium
Stratum 3E Quartz
Control
DDS (Direct Digital Synthesis) technology
Integrated CPU
Output Section
Port
20 Ports per module for DS/E1, 2048 kHz, and Composite clock
Signal Type
DS1
E1
2.048 MHz (G703 Sec.13)
Composite Clock (CC)
Table F-1. General Specifications (Continued)
Characteristics
Specification