12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide
89
Provisioning and Operating the SSU-2000
Establishing a Connection With the SSU-2000
3. Configure the emulation software for 8 data bits, no parity, 1 stop bit, and 9600
baud rate.
4. Start the terminal emulation software and press
Enter
. The system prompt
->
should appear. If it does not, recheck each step in this procedure.
5. For the initial installation, create an Administrator-level user as described in
Adding An Administrator-Level User to the System
, on page 91, before
proceeding with the Ethernet setup.
Figure 3-1.
Direct Connection Using the Serial Port