Vista Digital Mixing System
Date printed: 05.04.2005
SW V3.5
Vista 8 Differences 8-51
Targets with their respective connections can be selected by clicking on
them in the list on the general patch. Selected targets change their color to
pink to show their selection state.
Clicking on the
Map Currently Selected
button maps the patches for the
selected targets (the pink-colored ones) to the ProBel connect command
specified on the left.
With
Listen to messages
enabled, incoming connect messages are
mapped to the edit fields on the dialog. To select targets affected by this
connect command simply click on them in the target list of the general
patch (color is set to pink).
Make sure to always associate the same ProBel destination to the same set
of targets.
Any connection on the patch may be mapped to certain ProBel connect
commands. You are not limited just to outputs or inputs!
With
Send spontaneous messages
enabled, the appropriate CON-
NECTED message is sent whenever one of the defined patch combinations
matches the same combination as when they were defined.
Summary of Contents for Vista
Page 16: ...Vista Digital Mixing System 1 2 Introduction SW V3 3 Date printed 05 08 03 ...
Page 36: ...Vista Digital Mixing System 1 22 Introduction SW V3 3 Date printed 05 08 03 ...
Page 38: ...Vista Digital Mixing System 2 2 Desk Operation SW V3 3 Date printed 05 08 03 ...
Page 76: ...Vista Digital Mixing System 3 2 Parameters SW V3 3 Date printed 05 08 03 ...
Page 128: ...Vista Digital Mixing System 3 54 Parameters SW V3 3 Date printed 05 08 03 ...
Page 132: ...D950 Vista Digital Mixing System 4 4 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 148: ...D950 Vista Digital Mixing System 4 20 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 266: ...D950 Vista7 Digital Mixing System 5 4 AutoTouch SW V3 3 Date printed 27 08 03 ...
Page 464: ...Vista Digital Mixing System 6 2 Remote Bay SW V3 3 Date printed 05 08 03 ...
Page 468: ...D950 Vista Digital Mixing System 7 2 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 522: ...D950 Vista Digital Mixing System 7 56 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 588: ...Vista Digital Mixing System 9 10 Application Notes SW V3 3 V3 5 Date printed 26 10 07 ...
Page 692: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 31 ...
Page 696: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 35 ...