D950/Vista Digital Mixing System
Date printed: 05.08.03
SW V3.3
GC Operation 4-77
4.5.2.1.1
Machine/TC Generator Control
The settings and functions are:
Machine Control buttons:
Consist of Rewind, Fast Forward, Play, Stop, Record, Locate, GoTo and
Loop buttons. For added convenience, Play, Stop, Record, GoTo and Loop
are also featured on the control surface keyboard. The Machine Control
keys can be configured in the Option/TC-Reader/Generator Menu for:
•
None
: Both Machine Control key/button sets are disabled.
•
9-pin serial control
: Both Machine Control key/button sets control the
one 9-pin port.
This setting may be used to serially control a single transport, or to
control the optional multi-machine Motion Controller system.
•
Generator Control
: Both Machine Control key/button sets control the
TC2 or TC3 Timecode Generator. This setting is used for pre-striping
tapes with timecode data, or to control machine transports in TC chase
mode.
Locate Mode:
Loc
: The connected 9-pin machine will locate to the selected
From
time-
code address.
Loop Mode:
The Loop, Rehearse, and Drop-In (Auto Rec) selection operates in con-
junction with the Loop button:
•
Loop
:
The machine will play in an endless loop, starting with the
From
timecode setting, and ending with the
To
timecode value.
•
Rehearse
: The machine will play in an endless loop, starting with the
(
From – Pre-roll
) timecode setting, and ending with the (
To + Post-
roll
) timecode value. In addition, any machine tracks set to Ready will
go into a
simulated
Record function, starting with the
From
timecode
setting, and ending with the
To
timecode value.
•
Auto Rec
: The machine will play in an endless Loop, starting with the
(
From – Pre-roll
) timecode setting, and ending with the (
To + Post-
roll
) TC value. In addition, any machine track set to Ready will enter
Record mode, starting with the
from
, and ending with the
to
TC value.
Pre-roll time:
(A value set in the Option/TC-Reader/Generator Menu). This action al-
lows the operator to enter a Pre-roll time in timecode format. The con-
trolled audio or video machine will be parked
before
the actual drop-in
point given by the value “x” = Pre-roll time, and then synchronized in Play
mode (usually, Pre-roll is set to values from 3 to 5 s).
Post-roll time:
(A value set in the Option/TC-Reader/Generator Menu). This action al-
lows the operator to enter a Post-roll time in timecode format. The con-
trolled audio or video machine will be kept in synchronized Play mode
af-
ter
the actual drop-out point for the value “y” = Post-roll time (usually,
post-roll is set to about one second).
From/To Control:
This action allows the user to enter a start-timecode address (
From
) and an
end-timecode address (
To
) for the Locate, Loop, and GoTo functions. The
timecode values can be entered manually, using the control surface key-
board. You can also select any of the existing Cue Points by clicking on
the
Cue
button.
Note:
Rehearse and Auto-Rec modes are depending on the connected machine.
The feature has been tested with common Sony VCR machines. Studer
cannot guarantee proper function with all 9-pin machines being currently
on the market. However, some options exist for system administrator use
to adapt the 9-pin behavior of the D950/Vista to some machines (refer to
the
Service Manual
).
Summary of Contents for Vista
Page 16: ...Vista Digital Mixing System 1 2 Introduction SW V3 3 Date printed 05 08 03 ...
Page 36: ...Vista Digital Mixing System 1 22 Introduction SW V3 3 Date printed 05 08 03 ...
Page 38: ...Vista Digital Mixing System 2 2 Desk Operation SW V3 3 Date printed 05 08 03 ...
Page 76: ...Vista Digital Mixing System 3 2 Parameters SW V3 3 Date printed 05 08 03 ...
Page 128: ...Vista Digital Mixing System 3 54 Parameters SW V3 3 Date printed 05 08 03 ...
Page 132: ...D950 Vista Digital Mixing System 4 4 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 148: ...D950 Vista Digital Mixing System 4 20 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 266: ...D950 Vista7 Digital Mixing System 5 4 AutoTouch SW V3 3 Date printed 27 08 03 ...
Page 464: ...Vista Digital Mixing System 6 2 Remote Bay SW V3 3 Date printed 05 08 03 ...
Page 468: ...D950 Vista Digital Mixing System 7 2 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 522: ...D950 Vista Digital Mixing System 7 56 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 588: ...Vista Digital Mixing System 9 10 Application Notes SW V3 3 V3 5 Date printed 26 10 07 ...
Page 692: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 31 ...
Page 696: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 35 ...