Vista Digital Mixing System
Date printed: 05.04.2005
SW V3.5
Vista 8 Differences 8-17
8.4.2.3
Monitoring Source Selector
The 32 available monitoring source selectors act exactly the same as with
Vista 6. First select the target to be changed: Control Room (
CR
),
STUDIO A,
or
STUDIO B
. Then select the appropriate source key (
1…32
). All
keys are fully user-definable by using the monitoring setup dialog on the
control screen (accessible to system administrators only). Each key may
independently feed a set of one to eight loudspeakers. It is therefore possi-
ble to have a two-channel stereo source on one key, while another key se-
lects a 5.1 surround source. This makes the use of third-party equipment
for automatic mix-down of a 5.1 surround mix into a two-channel stereo
mix very easy: Feed the mix-down equipment with the 5.1 master mix and
feed its two output channels back to the console. Define one of the source
selector keys to switch these two channels onto left and right loudspeaker.
Note:
The
keys
1…4
may be used as “sub-selectors”, each opening up a choice of
twelve more sources on the control screen. This functionality is the same as
with Vista 6 and 7.
8.4.2.4
Option
Keys
These keys are intended for future software expansion. Current functions:
F3
If the cue list is “armed”, this key switches off/on all console lights.
F7
Used during live broadcasting; by pressing it, it is possible to de- and re-
activate the offline conference temporarily without loosing its member
definition. This key is a duplicate of the
conference icon in the GC
toolbar.
1
or sub-sel.
2
or sub-sel.
3
or sub-sel.
4
or sub-sel.
5
6
7
8
17
18
19
20
9
10
11
12
13
14
15
16
21
22
23
24
25
26
27
28
29
30
31
32
Summary of Contents for Vista
Page 16: ...Vista Digital Mixing System 1 2 Introduction SW V3 3 Date printed 05 08 03 ...
Page 36: ...Vista Digital Mixing System 1 22 Introduction SW V3 3 Date printed 05 08 03 ...
Page 38: ...Vista Digital Mixing System 2 2 Desk Operation SW V3 3 Date printed 05 08 03 ...
Page 76: ...Vista Digital Mixing System 3 2 Parameters SW V3 3 Date printed 05 08 03 ...
Page 128: ...Vista Digital Mixing System 3 54 Parameters SW V3 3 Date printed 05 08 03 ...
Page 132: ...D950 Vista Digital Mixing System 4 4 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 148: ...D950 Vista Digital Mixing System 4 20 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 266: ...D950 Vista7 Digital Mixing System 5 4 AutoTouch SW V3 3 Date printed 27 08 03 ...
Page 464: ...Vista Digital Mixing System 6 2 Remote Bay SW V3 3 Date printed 05 08 03 ...
Page 468: ...D950 Vista Digital Mixing System 7 2 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 522: ...D950 Vista Digital Mixing System 7 56 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 588: ...Vista Digital Mixing System 9 10 Application Notes SW V3 3 V3 5 Date printed 26 10 07 ...
Page 692: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 31 ...
Page 696: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 35 ...