D950/Vista7 Digital Mixing System
Date printed: 27.08.03
SW V3.3
Au 5-41
5.5.1.3
Kill Pass
The “Kill Pass” function prevents a new pass from being written if flaws
are detected while a new Mix Pass is being created. This is useful if a
mistake is made during a RECORD pass and the resultant pass would not
be worth keeping.
The
KILL PASS
key is located next to the
UNDO
/
REDO
keys in the Auto-
mation Panels.
D950:
Vista:
Killing a Mix Pass:
If
KILL PASS
is engaged when timecode is stopped, the new mix pass will
not be written. To prevent a new Mix Pass from being written, press the
KILL PASS
key
before
playback of timecode stops.
Note:
KILL PASS
may be engaged and disengaged at any time while timecode is
being played back. This allows the user to kill a pass and then change his
or her mind before the timecode is stopped. As long as timecode hasn’t
stopped, Kill pass may be toggled on an off at will. The Kill Pass state that
exists when timecode is stopped will dictate the fate of the Record Mix
Pass
KILL PASS
will always disengage at the end of a Mix Pass.
Conditions:
KILL PASS
functions only when RECORD passes are in progress.
<Option>
• With <Protect Static From Kill Pass> checked on the Misc Options
page, changes made to Static controls are retained when
KILL PASS
is
used; also refer to
chapter 5.21.8
.
Note:
The Mix Options window is opened by clicking the Options… button in
the Au window. Clicking the appropriate Tab will open the cor-
responding page.
Summary of Contents for Vista
Page 16: ...Vista Digital Mixing System 1 2 Introduction SW V3 3 Date printed 05 08 03 ...
Page 36: ...Vista Digital Mixing System 1 22 Introduction SW V3 3 Date printed 05 08 03 ...
Page 38: ...Vista Digital Mixing System 2 2 Desk Operation SW V3 3 Date printed 05 08 03 ...
Page 76: ...Vista Digital Mixing System 3 2 Parameters SW V3 3 Date printed 05 08 03 ...
Page 128: ...Vista Digital Mixing System 3 54 Parameters SW V3 3 Date printed 05 08 03 ...
Page 132: ...D950 Vista Digital Mixing System 4 4 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 148: ...D950 Vista Digital Mixing System 4 20 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 266: ...D950 Vista7 Digital Mixing System 5 4 AutoTouch SW V3 3 Date printed 27 08 03 ...
Page 464: ...Vista Digital Mixing System 6 2 Remote Bay SW V3 3 Date printed 05 08 03 ...
Page 468: ...D950 Vista Digital Mixing System 7 2 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 522: ...D950 Vista Digital Mixing System 7 56 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 588: ...Vista Digital Mixing System 9 10 Application Notes SW V3 3 V3 5 Date printed 26 10 07 ...
Page 692: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 31 ...
Page 696: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 35 ...