D950/Vista7 Digital Mixing System
5-52
Au
SW V3.3
Date printed: 27.08.03
• Engaging
READ LOCK
: All controls are placed in READ mode. All
mode changes are locked out, AUDITION mode is defeated, and only
written values will be heard.
<Option>
• <When Mix Status is Set to on> (also refer to
chapter 5.21.2
): Radio
buttons on the Control Modes Options page allow the selection of one
of the following options to take effect when Mix Status is set to on (af-
ter the first time AutoTouch has been turned on for the first time):
-
<Maintain Object Modes>: When the
MIX ON
key on the Automa-
tion Master Panel is turned off, all controls are isolated from auto-
mation and operate as manual controls. With <Maintain Object
Modes> selected, knowledge of the Control Mode for each control
is maintained. When the system is turned back on, the Control
Mode of all controls is restored.
-
<Set All to Read>: Turning the
MIX ON
key on, after having turned
it off, will set all controls to READ.
-
<Set Pre-Selector Objects to WRITE>: Any controls that are se-
lected in the Global Control Modes Pre-Selector will be set to
WRITE. All others will be set to READ.
-
<Set Pre-Selector Objects to TRIM>: Any controls that are selected
in the Global Control Modes Pre-Selector will be set to TRIM. All
others will be set to READ.
• With <Mode Enable sets non-selected to READ> checked on the Con-
trol Modes Options page, all controls not pre-selected are placed in
READ when a new Control Mode is enabled. In other words, only the
controls that have been Pre-Selected will enter the new mode and all
others change to READ.
• <First Time Automation is Turned ON>
(D950 only)
(also refer to
chapter 5.21.6
): Radio buttons on the Panel Preset Options page allow
the selection of one of the following options to take effect when Auto-
Touch+ is turned on for first time:
-
<Load Preset A>: Control Modes are entered according to the op-
tions that determine what happens when a Panel Preset is loaded.
Maintaining current modes, setting all to READ, and loading the
Mode stated stored within Preset A are possible.
-
<Use Last Setting>: The last used Control Modes are entered.
• <When Loading a Preset>: Radio buttons on the Panel Preset Options
page allow the selection of one of the following options to take effect
when a Panel Preset is loaded:
-
<Maintain Object Modes>: Loading a Panel Preset will not change
the control modes of any of the controls in the console. Current
modes will be retained.
-
<Set All to Read>: Loading a Panel Preset will set all controls to
READ.
-
<Apply Stored Control Mode>: The Control Modes and Pre-
Selectors stored within the recalled Preset will be applied.
Summary of Contents for Vista
Page 16: ...Vista Digital Mixing System 1 2 Introduction SW V3 3 Date printed 05 08 03 ...
Page 36: ...Vista Digital Mixing System 1 22 Introduction SW V3 3 Date printed 05 08 03 ...
Page 38: ...Vista Digital Mixing System 2 2 Desk Operation SW V3 3 Date printed 05 08 03 ...
Page 76: ...Vista Digital Mixing System 3 2 Parameters SW V3 3 Date printed 05 08 03 ...
Page 128: ...Vista Digital Mixing System 3 54 Parameters SW V3 3 Date printed 05 08 03 ...
Page 132: ...D950 Vista Digital Mixing System 4 4 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 148: ...D950 Vista Digital Mixing System 4 20 GC Operation SW V3 3 Date printed 05 08 03 ...
Page 266: ...D950 Vista7 Digital Mixing System 5 4 AutoTouch SW V3 3 Date printed 27 08 03 ...
Page 464: ...Vista Digital Mixing System 6 2 Remote Bay SW V3 3 Date printed 05 08 03 ...
Page 468: ...D950 Vista Digital Mixing System 7 2 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 522: ...D950 Vista Digital Mixing System 7 56 ConfigTool SW V3 3 Date printed 05 08 03 ...
Page 588: ...Vista Digital Mixing System 9 10 Application Notes SW V3 3 V3 5 Date printed 26 10 07 ...
Page 692: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 31 ...
Page 696: ...Vista Digital Mixing System Date printed 20 08 09 SW V4 1 Software V4 1 35 ...