USO
RESTRITO
Serial Port Settings (Serial Port Assign Menu)
645
Knob
Parameter
Adjustment
Setting values
2
Action
Action selection
1 to maximum
value
a)
5
Reg No
Snapshot
register number
1 to 4
b)
5
GPI No
GPI number
selection
1 to 32
c)
Ch
a
p
te
r 22
DCU
S
e
tu
p
(
DC
U)
When “ ” is selected as the trigger polarity, there is
no Pulse Width setting. When “Status” is selected,
there is no Pulse Width or Timing setting.
4
In the <Source Device> group, select the control panel
or DCU to handle the GPI output.
SCU1:
ID1 control panel (PNL1)
SCU2:
ID2 control panel (PNL2)
SCU3:
ID3 control panel (PNL3)
DCU1:
ID1 DCU
DCU2:
ID2 DCU
When the action set in the following step
5
is carried
out on the control panel selected here, this causes a
GPI output. It is also possible to output error
information. When the DCU is selected, you can
output error information by means of the action set in
step
5
.
5
Using any of the following methods, select the action
you want to set.
•
Press directly on the list in the status area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knobs.
Serial Port Settings
(Serial Port Assign Menu)
To set the protocol to match a device connected to a 9-pin
serial port, display the DCU >Serial Port Assign menu.
To display the Serial Port Assign menu
In the Engineering Setup menu, select VF5 ‘DCU’ and
HF5 ‘Serial Port Assign.’
The serial port setting status appears in the status area.
Making Serial Port Settings
1
In the DCU >Serial Port Assign menu, select the target
for the setting (DCU1 or DCU2) from the <DCU
Select> group.
2
Using any of the following methods, select the serial
port.
•
Press directly on the list on the left of the status area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knob.
Knob
Parameter
Adjustment
Setting values
1
Port No
Serial port
1 to maximum
value
a)
a)
Action list when the trigger type is other than “Status”
In M/E-x, the x is the M/E bank number (1 to 5); in Keyx the x is the
key number (1 to 8); in DSKx the x is the DSK number (1 to 8).
When Source Device is SCU: M/E-x Keyx SS ? Recall, P/P DSKx
SS ? Recall, Editor GPI-?? (only when BZS-8050 license is valid),
No Action
When Source Device is DCU: No Action
Action list when the trigger type is “Status”
In M/E-x, the x is the M/E bank number (1 to 5); in Keyx the x is the
key number (1 to 8); in DSKx the x is the DSK number (1 to 8).
When Source Device is SCU: M/E-x Keyx SS ? Recall, P/P DSKx
SS ? Recall, M/E-x Keyx On, P/P DSKx On, Error Make, Error
Break, Keep Make, Keep Break, Device Recording, No Action
When Source Device is DCU: Error Make, Error Break, No Action
b)
When knob 2 selection is “Key Snapshot”
c)
When knob 2 selection is “GPI”
6
To confirm the selection, press [Action Set].
This confirms the selection, which appears in the
status area.
Test firing the trigger
In the DCU >GPI Output menu press [Test Fire].
This outputs a trigger from the selected output port. This is
not output when the trigger type is “Status.”
a)
The setting value range depends on the DCU port setting. When the
MKS-2700 is connected, select 2 for the slot and a value in the range
1 to 6 for the port.
3
Using any of the following methods, select the
protocol for the connected device.
•
Press directly on the list on the right of the status
area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knob.
Knob
Parameter
Adjustment
Setting values
2
Device
Type
Protocol
selection
1 to 10
a)
a) 1. No Assign: nothing is connected to the serial port.
2.
P-Bus: P-Bus device.
3.
VTR: VTR
4.
DDR SD9P: disk recorder (Sony disk 9-pin protocol)
5.
DDR VDCP: disk recorder (video disk communication protocol)
6.
Simple VDCP: disk recorder with low-performance
communications (video disk communications protocol)
7.
DDR Odetics: disk recorder (Odetics protocol)
8.
Extended VTR (Abekas A53 protocol)
9.
Mixer ESAM-II
10.
AS ES-BUS: device supporting the AS ES bus protocol
Summary of Contents for MVS-8000X SystemMVS-7000X System
Page 358: ...USO RESTRITO 358 Wipe Pattern List Appendix Volume 1 Enhanced Wipes Rotary Wipes ...
Page 360: ...USO RESTRITO Random Diamond DustWipes 360 1 w pe PaternLO ...
Page 362: ...USO RESTRITO 362 DME Wipe Pattern List Appendix Volume 1 Door 2D trans 3D trans ...
Page 364: ...USO RESTRITO 364 DME Wipe Pattern List Appendix Volume 1 Page turn Page roll ...
Page 377: ...USO RESTRITO Menu Tree 377 Appendix Volume 1 AUX Menu AUX button CCR Menu CCR button ...
Page 379: ...USO RESTRITO Menu Tree 379 Appendix Volume 1 DME Menu DME button ...
Page 381: ...USO RESTRITO Menu Tree 381 Appendix Volume 1 Macro Menu MCRO button ...
Page 382: ...USO RESTRITO 382 Menu Tree Appendix Volume 1 Key Frame Menu KEY FRAME button ...
Page 383: ...USO RESTRITO Menu Tree 383 Appendix Volume 1 Effect Menu EFF button ...
Page 384: ...USO RESTRITO 384 Menu Tree Appendix Volume 1 Snapshot Menu SNAPSHOT button ...
Page 385: ...USO RESTRITO Menu Tree 385 Appendix Volume 1 Shotbox Menu SHOTBOX button ...
Page 386: ...USO RESTRITO 386 Menu Tree Appendix Volume 1 File Menu FILE button ...