GPI Input Setting (GPI Input Assign Menu)
Knob
Parameter
Adjustment
Setting
values
2
Action
Action selection
1 to maximum
value
a)
4
Aux Bus
No
AUX bus
selection
1 to 48
b)
5
Reg No
Register number
1 to 4
c)
1 to 99
d)
1 to 250
e)
1 to 399
f)
5
Src No
Source signal
selection
1 to maximum
value
b) g) h)
Ch
a
p
te
r 22
DCU
S
e
tu
p
(
DC
U)
a)
As for the setting values, see “Selectable actions for various trigger
types”
b)
When knob 2 selection is “Aux ? O’ride Src ??”
c)
When knob 2 selection is “Key Snapshot”
d)
When knob 2 selection is “Snapshot” or “Shotbox”
e)
When knob 2 selection is “Macro”
f)
When knob 2 selection is “Effect”
g)
The following values apply to the MVS-8000X.
For primary inputs: 1 to 144
For premium inputs: 145 to 164 ((PREM1) to (PREM20) indicated
after the number)
For format converter dedicated inputs: 165 to 180 ((FC1) to (FC16)
indicated after the number)
h)
The values from 1 to 80 apply to the MVS-7000X.
5
To confirm the setting in step
4
, press [Action Set].
This confirms the setting, which appears in the status
area.
Selectable actions for various trigger types
•
When the trigger type is other than “Level”
In M/E-x, the x is the M/E bank number (1 to 5); in
DSKx the x is the DSK number (1 to 8); in Keyx the x is
the key number (1 to 8).
M/E-x Cut, M/E-x Auto Trans, P/P Cut, P/P Auto Trans,
M/E-x Keyx Cut, M/E-x Keyx Auto Trans, P/P DSKx
Cut, P/P DSKx Auto Trans, FTB Auto Trans, FTB Cut,
Master SS ? Recall, SS ? Recall, M/E-x Keyx SS ?
Recall, P/P DSKx SS ? Recall, Master Effect ? Recall,
Effect ? Recall, Effect ? Recall & Run, KF Run, KF
Stop, KF Rewind, FM Src1 Field Freeze, FM Src1
Frame Freeze, FM Src1 Freeze Off, FM Src2 Field
Freeze, FM Src2 Frame Freeze, FM Src2 Freeze Off, FM
Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip
Record, FM Src2 Clip Stop, FM1 to FM8 Clip Cueup,
FM1 to FM8 Clip Play, FM1 to FM8 Clip Stop, Shotbox
? Recall, Macro Take, Macro ? Recall, No Action
•
When the trigger type is only “Rising Edge” or
“Falling Edge”
Aux? O’ride Src ??
•
When the trigger type is “Level”
In M/E-x, the x is the M/E bank number (1 to 5).
System Format, System Aspect, M/E-x Aspect, P/P
Aspect, DME Ch1 Aspect, DME Ch2 Aspect, DME Ch3
Aspect, DME Ch4 Aspect, DME Ch5 Aspect, DME Ch6
Aspect, DME Ch7 Aspect, DME Ch8 Aspect, Level
Enable, Panel Status, No Action
Notes
•
“Level Enable” is a function that determines whether
GPI inputs are enabled (“Enable”) or disabled
(“Disable”) for the “System Aspect” and “System
Format” actions that can be used when the trigger type is
Level. When Level Enable is used, if the input is
“Disable” then it is not possible to switch “System
Aspect” or “System Format” by GPI input.
If a GPI to switch “System Aspect” or “System Format”
occurs when powering the system off, the action
triggered by the GPI may start immediately before the
power goes off and the power may go off before the
action is completed. This may corrupt the setup settings.
It is therefore recommended to use Level Enable to avoid
such a situation.
•
As for “Aux ? O’ride Src ??,” when “Rising Edge” is
selected, on a rising edge the set AUX bus input is used.
On a falling edge, the original state of the cross-point is
restored. If the GPI trigger is applied repeatedly at short
intervals (0.5 second or less), the cross-point switching
may not be carried out correctly. In this case, apply the
GPI trigger again.
•
If “System Format” is selected for “Action” when the
format converter is used on the switcher, you can set the
conversion format of the format converter for “FC Input
1-4,” “FC Input 5-8,” “FC Input 9-12” (MVS-8000X
only), “FC Input 13-16” (MVS-8000X only), “FC
Output 1-2,” and “FC Output 3-4.”
•
In Dual Simul mode, you can select the target switcher
for the panel status display using “Panel Status”
(H=SWR1, L=SWR2).
Carrying out level settings
To set the low level and high level, first set the trigger type
to “Level,” then use the following procedure.
1
In the DCU >GPI Input Assign menu, select the action
to be set, and press [H/L Set].
The H/L Set menu appears.
2
Using any of the following methods, select the
settings.
•
Press directly on the list in the status area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knob.
Knob
Parameter
Adjustment
Setting values
1
No
Signal format/
screen aspect
ratio selection
1 to maximum
value
3
To apply the selection made in step
2
when the input
is the GPI high level, press [H Set]. To apply the
Summary of Contents for MVS-8000X SystemMVS-7000X System
Page 358: ...USO RESTRITO 358 Wipe Pattern List Appendix Volume 1 Enhanced Wipes Rotary Wipes ...
Page 360: ...USO RESTRITO Random Diamond DustWipes 360 1 w pe PaternLO ...
Page 362: ...USO RESTRITO 362 DME Wipe Pattern List Appendix Volume 1 Door 2D trans 3D trans ...
Page 364: ...USO RESTRITO 364 DME Wipe Pattern List Appendix Volume 1 Page turn Page roll ...
Page 377: ...USO RESTRITO Menu Tree 377 Appendix Volume 1 AUX Menu AUX button CCR Menu CCR button ...
Page 379: ...USO RESTRITO Menu Tree 379 Appendix Volume 1 DME Menu DME button ...
Page 381: ...USO RESTRITO Menu Tree 381 Appendix Volume 1 Macro Menu MCRO button ...
Page 382: ...USO RESTRITO 382 Menu Tree Appendix Volume 1 Key Frame Menu KEY FRAME button ...
Page 383: ...USO RESTRITO Menu Tree 383 Appendix Volume 1 Effect Menu EFF button ...
Page 384: ...USO RESTRITO 384 Menu Tree Appendix Volume 1 Snapshot Menu SNAPSHOT button ...
Page 385: ...USO RESTRITO Menu Tree 385 Appendix Volume 1 Shotbox Menu SHOTBOX button ...
Page 386: ...USO RESTRITO 386 Menu Tree Appendix Volume 1 File Menu FILE button ...
Page 391: ...USO RESTRITO Menu Tree 391 Appendix Volume 1 ENG SETUP button to previous pages ...
Page 413: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...
Page 706: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...