Names and Functions of Parts of the Control Panel
47
Name
Description
SHIFT/CLR
WORK
BUFR (clear
work buffer)
• Pressing this button once returns the two-
dimensional transformation settings to the
defaults.
• Pressing the [CLR WORK BUFR] button
twice, or holding down the [SHIFT] button
and pressing the [CLR WORK BUFR]
button returns all resizer parameter values
to the defaults.
X, Y, Z
These restrict the axes affected by the
trackball and Z-ring to the X-, Y- or Z-axis.
SHIFT/CTR
(center)
• Pressing this button once changes the two-
dimensional transformation settings to the
closest detent values.
• Pressing the [CTR] button twice, or holding
down the [SHIFT] button and pressing the
[CTR] button returns the two-dimensional
transformation values to the defaults.
Name
Description
LOC SIZE
(ASP:
aspect)
• Pressing this button and operating the
trackball or Z-ring changes the aspect ratio
of a key to which the resizer function is
applied to.
• When this button is held down, the trackball
or Z-ring operation is switched to fine
control (fine mode).
LOC XYZ
(LOC:
location)
• Pressing this button and operating the
trackball or Z-ring moves, shrinks, or
magnifies a key to which the resizer
function is applied.
• When this button is held down, the trackball
or Z-ring operation is switched to fine
control (fine mode).
ROT
(RSZR:
resizer)
Press this button, turning it on, to enable the
resizer.
ASP PS
(ROT:
Rotation)
• Pressing this button and operating the
trackball or Z-ring rotates the key to which
the resizer function is applied or adjusts
perspective.
• When this button is held down, the trackball
or Z-ring operation is switched to fine
control (fine mode).
Ch
a
p
te
r 2
M
e
n
u
s
and
Co
n
tr
o
l P
a
n
e
l
Name
Description
CTR
(center)
• When this button is pressed, the pattern
position returns to the center.
• When the [USER] button is selected, the
pattern size also returns to 50.00.
CLR WORK
BUFR
Press this button twice in rapid succession to
reset all parameters on the target M/E or
PGM/PST to their initial values.
a)
Among these buttons, you can select multiple buttons.
b)
By setting the operation mode in setup, you can select keys 5 to 8 with
these buttons. In this case, it is not possible to select more than one of keys
1 to 8.
When the three-dimensional transform operation
mode is enabled
The buttons are used for three-dimensional DME
transformations.
For details, see “Three-Dimensional Transformation
Operations” (page 283).
When the VTR/disk recorder/frame memory operation
mode is enabled
The buttons are used for VTR control or playback of frame
memory clips.
For details, see “Controlling the Tape/Disk Transport” in
Chapter 12 (Volume 2).
When the resizer control mode is enabled
c
Trackball
The effect of operation depends on the operating mode as
follows.
When the positioner operation mode is enabled
By moving this, you can move the pattern in the X-axis and
Y-axis directions.
When the three-dimensional transform operation
mode is enabled
Move the trackball to control the X- and Y-axes in a three-
dimensional transform.
When the [SRC] or [TRGT] button is held down, the
trackball operation is switched to fine control (fine mode).
When the resizer control mode is enabled
By turning the trackball, you can move in the X and Y
directions of the key to which the resize is applied, change
the aspect ratio, and rotate around the X-axis and Y-axis.
When the [LOC SIZE], [LOC XYZ], or [ASP PS] button
is held down, the trackball operation is switched to fine
control (fine mode).
d
Z-ring
The effect of operation depends on the operating mode as
follows.
When the positioner operation mode is enabled
When the [USER] button is selected, by turning the ring
you can adjust the size of the pattern.
When the three-dimensional transform operation
mode is enabled
Turn this ring to control the Z-axis in a three-dimensional
transform.
When the [SRC] or [TRGT] button is held down, the Z-
ring operation is switched to fine control (fine mode).
Summary of Contents for MVS-8000X SystemMVS-7000X System
Page 358: ...USO RESTRITO 358 Wipe Pattern List Appendix Volume 1 Enhanced Wipes Rotary Wipes ...
Page 360: ...USO RESTRITO Random Diamond DustWipes 360 1 w pe PaternLO ...
Page 362: ...USO RESTRITO 362 DME Wipe Pattern List Appendix Volume 1 Door 2D trans 3D trans ...
Page 364: ...USO RESTRITO 364 DME Wipe Pattern List Appendix Volume 1 Page turn Page roll ...
Page 377: ...USO RESTRITO Menu Tree 377 Appendix Volume 1 AUX Menu AUX button CCR Menu CCR button ...
Page 379: ...USO RESTRITO Menu Tree 379 Appendix Volume 1 DME Menu DME button ...
Page 381: ...USO RESTRITO Menu Tree 381 Appendix Volume 1 Macro Menu MCRO button ...
Page 382: ...USO RESTRITO 382 Menu Tree Appendix Volume 1 Key Frame Menu KEY FRAME button ...
Page 383: ...USO RESTRITO Menu Tree 383 Appendix Volume 1 Effect Menu EFF button ...
Page 384: ...USO RESTRITO 384 Menu Tree Appendix Volume 1 Snapshot Menu SNAPSHOT button ...
Page 385: ...USO RESTRITO Menu Tree 385 Appendix Volume 1 Shotbox Menu SHOTBOX button ...
Page 386: ...USO RESTRITO 386 Menu Tree Appendix Volume 1 File Menu FILE button ...
Page 391: ...USO RESTRITO Menu Tree 391 Appendix Volume 1 ENG SETUP button to previous pages ...
Page 413: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...
Page 706: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...