9-11
DVW-250/250P
9-4. Audio System Adjustment
4.
Play back a 12 kHz, -20 VU portion (TIME;04 : 00 :
00 - 04 : 24 : 29) of the alignment tape.
Equipment
:
Audio Analyzer
Test point
:
AUDIO OUT CH-4 connector on
the connector panel
Adjustment point
:
1
RV801 (G-1 : B) /EQ-54
Specification
:
A
±
0.7 dBm (600
Ω
)
5.
Perform STEP 1 again.
6.
Eject the tape.
7.
Setting after adjustment
Reset switches to the former positions.
9-4-6. CUE Bias Adjustment
Preparation
• Disconnect the cable from the AUDIO IN CH-4 connec-
tor/connector panel.
• CUE REC switch/connector panel
→
ON
• MODE switch/connector panel
→
PB/EE
Adjustment procedure
1.
Insert a blank tape and put into the REC mode.
2.
Equipment
:
Audio noise meter
Test point
:
TP804 (G-1 : B) /EQ-54
GND
:
TP805 (G-1 : B) /EQ-54
Adjustment point
:
1
CV800 (G-2 : A or B) /EQ-54
Specification
:
18
±
1 mV rms
3.
Equipment
:
Oscilloscope
Test point
:
TP803 (G-2 : B) /EQ-54
Specification
:
Check that the level is 1.8 Vp-p or
less.
4.
Repeat steps 2 and 3 until the specifications (steps 2
and 3) are met.
1.8 Vp-p or less
EQ-54 Board B side
1
A
B
C
D
E
F
G
2
3
4
TP803
RV801 RV802
TP804
RV803
TP805
EQ-54 Board A side
1
2
3
4
A
B
C
D
E
F
G
CV800