7-37
DVW-250/250P
7-2-15. Drum PG Phase Adjustment
Tools
• Alignment tape ZR2-1
8-960-073-11
• Alignment tape ZR2-1P
8-960-073-61
• Oscilloscope
• Regulated DC power supply
(AC-550/550CE or equivalent)
Setting
1.
Turn the power off.
2.
Remove the top panel.
(Refer to “1-5. Removal/Installation of Cabinet”.)
3.
Set the DIP switches.
(Refer to “7-2-4. DIP switch Setting”.)
4.
Remove the ornamental plate on the left side panel.
(Refer to “1-13. Tracking Adjustment”.)
5.
Connect an oscilloscope.
CH-1: TP10/MB-601
CH-2: TP8/MB-601
6.
Connect a regulated DC power supply to DC IN
connector on the connector panel.
7.
Turn the power on.
8.
Insert an alignment tape ZR2-1/1P.
9.
On the setup menu, set AUTO TRACKING to OFF.
10. Turn the tracking control volume to the mechanical
center(click position).
7-2-15. Drum PG Phase Adjustment