7-51
DVW-250/250P
7-3-1. Tension Regurator Adjustment
Adjusting table
7-3. Mechanical Alignment
7-3-1. Tension Regurator Adjustment
Tools
• FWD back tension mesuring cassette
:J-6323-890-A
• S-tension arm positioning pin
:J-7031-030-A
• Weight for S-tension adjustment(W76.7):J-7031-040-A
• Weight for S-tension (W44)
:J-7031-050-A
• S-TEN adjusting table
:J-7031-280-A
• End sensor positioning tool
:J-7031-450-A
• Digital volt meter
• Digital Betacam cassette BCT-D40
:Standard product
• Regurated DC power supply
(AC-550/550CE or euivalent)
Setting
1.
Turn the power off.
2.
Remove the top panel.(Refer to “1-5.Removal/
Installation of Cabinet” maintenance manual part1)
3.
Set the S-TEN adjusting table on the horizontal board
so that the table leaves a fit space.
4.
Open the battery lid on the left side panel.
5.
Lay the DVW-250/250P on the S-TEN adjusting table
left side down.
6.
Connect an digital volt meter.
prove(+) : “TP7” pin on the MB-601 board
prove(-) : “E1” ground pin on the MB-601 board
7.
Connect a regurated DC power supply to DC IN
connector on the connector pannel.
8.
Turn the power on.