![Sony DVW-250 Maintenance Manual Download Page 178](http://html.mh-extra.com/html/sony/dvw-250/dvw-250_maintenance-manual_410988178.webp)
7-4
DVW-250/250P
7-1-4. Preparations
Before adjustments in this section, perform as follows.
(1) Turn the power off.
(2) Remove the top panel. (Refer to “1-5. Removal/Installation of Cabinet”.)
(3) Clean the following places using a cleaning piece moistened with cleaning fluid.
(Refer to “5-1. Cleaning”.)
• Video head
• Tape running surface of upper drum
• Tape running surface and lead of the lower drum
• Stationary heads
• Tape cleaner
• All tape guides
• Capstan shaft
• Pinch roller
7-1-5. Tools
Use the following tools in this section.
• Tape guide adjustment screwdriver
J-6321-500-A
• Tape guide driver spare bit
J-6322-420-3
• Inspection mirror (Small oval type)
J-6080-840-A
• Cleaning piece
2-034-697-00
• Cleaning fluid
9-919-573-01
• Torque screwdriver (for 3 kg)
J-6325-400-A
• Torque screwdriver bit (for M2)
J-6325-380-A
• Torque screwdriver hex. bit (across 1.27 mm)
J-7031-460-A
• Alignment tape ZR2-1
8-960-073-11
• Alignment tape ZR2-1P
8-960-073-61
Contents
*
The CTL head height adjustment can use at any position of this alignment tape.
TIME
min.:sec.
CTL TRACK
CUE TRACK
VIDEO/AUDIO
TRACK
00 : 00
(7 : 3 PULSE)
CTL
1 kHz, 0 VU
4MHz
(A CH only)
15 : 00
CTL
12 kHz, 0 VU
A,C CH-4MHz
B,D CH-8MHz
20 : 00
25 : 00
27 : 00
CTL
12 kHz, 0 VU
16MHz
(ALL CH)
CTL
50% FLAT FIELD
(ALL CH)
• Video tracking adustment
• CTL head position adustment
• CUE head height adustment
• CUE/TC head position adustment
• CUE/TC head azimuth adustment
• CUE/TC head head-to-tape contact adustment
USE
• PG adustment
7-1-4. Preparations
7-1-5. Tools