9-19
DVW-250/250P
9-5-6. ADC Sampling Phase Adjustment
n
Use the identical probes of the oscilloscope.
Adjustment procedure
1.
Insert an alignment tape (ZR5-1/P) and put the unit
into the PB mode.
2.
Oscilloscope settings
• AC mode
• 20 MHz BW Limit:OFF
• Set the GND levels of CH-1 and CH-2 are at the
center of the oscilloscope.
3.
A/Ech Adjustment
Test point
:
TP104 (A-3:B) /EQ-54
TRIG
:
TP105 (A-3:B) /EQ-54
Adjustment point
:
1
CV100 (A-2:B) /EQ-54
Specification
:
A = 0
±
2 ns
9-5. RF System Adjustment
EQ-54 Board B side
1
A
B
C
D
E
F
G
2
3
4
TP405
TP305
TP205
TP105
RV104
TP204
TP304
TP404
CV100
CV200
CV300
CV400
RV100
RV200
RV300
RV400
RV304
RV404
RV204
TP104
4.
Adjust the B/F, C/G, D/H channels in the same way.
Test point
TRIG
Adjustment point
B/Fch
TP204 (C-3:B)
TP205 (C-3:B)
1
CV200 (B-2:B)
C/Gch TP304 (D-3:B)
TP305 (D-3:B)
1
CV300 (D-2:B)
D/Hch TP404 (F-3:B)
TP405 (E-3:B)
1
CV400 (E-2:B)
5.
Eject the tape.
A
1
2
3
B
C
D
E
F
TP12
TP13
TP11
MB-601 Board A side