Introduction to the SKF GX Series Microlog
Battery Operations
•
Replace with a fully charged battery pack and re-latch.
•
Press the
Power
button.
The CMXA 75-
SL
-Z2 Microlog requires you to re-enter the Microlog’s date and time
when the main battery is disconnected.
How to Charge the Battery Pack
The Microlog's Lithium
-Ion battery packs (CMAC 5031) charge fully in 3-5 hours in the
Microlog. To prevent overcharging, an internal monitoring circuit shuts power off to the
battery once it reaches full capacity.
IMPORTANT
- Charge the battery fully before using the Microlog.
The battery is charged in the Microlog using the power supply. The Microlog is usable
while the battery is charging.
To charge a battery pack in the Microlog:
•
Ensure the power source is plugged into a wall outlet.
•
Insert the power source into the
POWER
connector at the top of the Microlog.
Battery Maintenance
Dispose your SKF Microlog Analyzer battery according to your local regional
requirements. If you are unable to dispose the battery locally, contact an SKF
Certified Repair depot to request a Return Authorization (RA) number to return the
battery to SKF for recycling. You may obtain an RA number from the SKF website
at www.skf.com/cm.
Use the following recommendations to prolong the life of your battery:
•
If a GX unit is temporarily not in use (and therefore not being regularly charged), it
is important that it is recharged at least every 25 to 30 days to prevent damage to
the cells.
•
If the GX battery pack is left outside the GX unit, it is important that it is recharged
every 12 months to prevent damage to the cells.
•
It is recommended to recalibrate the electronic "fuel gauge" (i.e.,
State Of Charge
meter) after approximately every 30th recharge. This prevents the fuel gauge from
showing an incorrect battery charge percentage. To do this, fully discharge the GX
battery pack and then fully charge it without any interruptions, ideally with the unit
in suspend mode (off).
•
It will take longer to charge the battery if the GX unit is switched on during
charging. Recharge the instrument while the unit is in suspend mode (off) for the
quickest recharge time.
•
The battery capacity (the length of unit's operational / run time) will be reduced at
temperature extremes (i.e., both high and low operating temperatures will reduce
the amount of time the unit runs from the battery pack).
SKF Microlog - GX Series
1 - 21
User Manual