Machinery Balancing Module
How to Perform a 1
-2 Plane with Prognosis Procedure
If you press the
2-Plane
function button, the dynamic 2 plane balancing procedure
resumes. Reference the previous
How to Perform a Dynamic 2 Plane Procedure
section for instructions on how to complete the 2-plane procedure.
If you press the
1-Plane
function button, in following 2 plane Correction Run screens,
all
Plane B
/
CH2
fields are marked as
N/A
(not applicable).
Add a Correction Weight to Plane A
Figure 5 - 37.
Example of a 2-
Plane Correction Weight Screen W
hen
You
Select to Proceed with a 1-Plane Prognosis.
Now t
he
Correction Weight
screen displays the permanent
Corr
ection
weight
,
Angle
,
and
Radius
balance solutions for Plane A at the top of the screen (Plane B settings are
marked
N/A
), and correction weight options at the bottom.
•
Stop the machine
, remove the temporary trial weights (if appropriate), and securely
attach the permanent correction weights at the precise angles and radii specified.
The
Split Weight
,
Add/Remove
,
Correction
, and
Combine All
fields – and the
Actual
function button all operate as described in the previous
How to Perform a Single-
Plane Procedure
section.
In all
Correction Weight
fields, use the up / down / right / left
arrow buttons to move between fields.
5 - 44
SKF Microlog - GX Series
User Manual