![SKF Microlog GX Series User Manual Download Page 29](http://html1.mh-extra.com/html/skf/microlog-gx-series/microlog-gx-series_user-manual_1287103029.webp)
Introduction to the SKF GX Series Microlog
Battery Operations
Battery Operations
Power Adapter/Battery Charger
The Microlog's Power Adapter/Battery Charger (CMAC 5090) converts AC power to DC
power required by the GX Series Microlog. The Power Adapter/Battery Charger kit
includes a USB/Power Splitter Cable (CMAC 5095) that provides connections between
the Microlog, the Power Adapter/Battery Charger, and an external device’s USB
communications port.
You can connect the Power Adapter/Battery Charger with your M
icrolog turned on or
off. The Power Adapter/Battery Charger works with AC power sources worldwide.
However, verify that you have a power cable designed for use in your country.
If you are running your Microlog on AC power with a battery
installed, the AC Power Adapter/Battery Charger charges the
battery (if needed), then maintains the battery's charge.
WARNING! The Power Adapter/Battery Charger should be placed in a
ventilated area (i.e., on a desktop) when used to power the Microlog or charge the
battery. Do not use the Power Adapter/Battery Charger in a poorly ventilated area,
as overheating may occur, possibly resulting in a fire.
Install and Charge the Microlog Battery
Prior to using the Micro
log for the first time, place the Lithium
-Ion battery pack (CMAC
5031) in the Microlog and charge the Lithium Ion battery for at least 24 hours to
ensure the battery is fully charged. The Microlog's battery charges when the Microlog is
connected to its AC power adapter/battery charger.
You can operate the Microlog from the external power
adapter/battery charger while waiting for the battery to charge.
Once the Microlog battery is fully charged (or the Microlog is connected to the Power
Adapter/Battery Charger), it is ready for operation.
Battery Life
Primary power for Microlog is provided by battery packs. The battery packs operate for
8 hours in typical operating environments, although the actual per-charge life can vary
drastically depending on conditions, equipment options, and usage patterns.
The battery status displays in the top right corner of the title bar.
•
Press the (.) key to display the amount of battery power remaining. A dialog
displays battery status.
Good
– Approximately 25% or more of battery life remains (i.e., approximately
4 hours of normal usage).
Low
-
Less than 25% of battery life remaining (approximately 2 hours), charge
the battery as soon as possible.
SKF Microlog - GX Series
1 - 19
User Manual