Machinery Balancing Module
How to Perform a 1
-2 Plane with Prognosis Procedure
Perform the Trial Run for Plane A
•
With the trial weight securely attached to the machine,
start the machine
and bring
it back up to the same speed used with the reference run (initial run).
•
Press an Enter / Fire button. Plane A’s Trial Run
screen displays.
•
Initially the trial run screen does not show data. Press the
Start
button or an
Enter / Fire key to record the trial run.
Figure 5 - 35.
Plane A’s Trial Run Screen.
Plane A’s Trial Run screen shows vibration magnitude and phase readings with the trial
weight attached.
•
From the Plane A’s
Trial Run
screen, after
Stop
ping data collection, press an
Enter / Fire button as if you were going to proceed to enter Plane B’s trial weight
setting. Before doing so, you are prompted whether the trial weight for plane A will
be removed, answer appropriately.
5 - 42
SKF Microlog - GX Series
User Manual