Run Up / Coast Down Module
How to Set Up a RUCD Measurement
ICP Supply –
(
On
or
Off
),
(Not editable if a preconfigured sensor is selected in the
Sensor
field.) When the
Variable
sensor is selected, select to turn ICP power
Off
or
On
for the sensor.
Input Range
- Specifies the maximum expected signal range for the incoming signal.
Ensure that the specified range can accommodate unexpected events. If in doubt, err
on the side of caution and set levels 10 to 20 times higher than expected.
Precision
– (
Low
,
Normal
,
High
, or
Very High
), Specify the desired data resolution.
Note that higher resolution data requires more processing time.
This setting
determines Max Rec. Time and Sample Freq. settings, as displayed in the screen’s
message area.
Mode – (Runup, Manual, or Coastdown)
, Specify the data collection mode.
Runup
- waits for an increase in speed from the tachometer signal to initiate
data capture.
Manual
- captures data irrespective of shaft speed, and is initiated by a key-
press to start recording data (can be used when no tacho signal is available).
Coastdown
- waits for a decrease in speed.
Pulses/Rev
- Sets the number of pulses per shaft revolution expected from the
tachometer output. The setting can be a multiple or a non-integer to accommodate
gear ratios, etc.
Tip
– To acquire a suitable tachometer signal, the tach. signal
should be approximately 1.5 volts peak-to-peak. The adverse
effect of excessively short tacho pulse widths can be addressed by
increasing the
Max No. Orders
setting to a higher value in order
to increase the sampling rate.
Start Spd (RPM)
- Sets the speed at which the RUCD starts recording data.
Stop Spd (RPM)
- Sets the speed at which the RUCD stops recording data.
Save To –
(
Internal
or
SD Card
), Specify the medium to record to, either the Microlog’s
Internal hard drive (not recommend due to large .wav file size) or an inserted SD card
(recommended). In the screen’s message area, the maximum recording time is
determined by the measurement’s settings and the free space available on the specified
medium. (Affects maximum recording time).
Max Acq Time(s)
- Sets the maximum permissible data acquisition time in seconds.
The information panel displays the maximum recording time as regulated by the
specified memory type. Also in the information panel, the sampling frequency at which
the data will be digitised is provided for information only.
•
Save
– If desired, from the measurement setup screen, you may press the
Save
function button to save the measurement setup for easy reuse in the future.
Reference
Chapter 4, The Analyzer Module
section on
Saving Analyzer
Measurement Results
for details on how to save your measurement setup.
SKF Microlog - GX Series
7 - 5
User Manual