![SKF Microlog GX Series User Manual Download Page 153](http://html1.mh-extra.com/html/skf/microlog-gx-series/microlog-gx-series_user-manual_1287103153.webp)
Machinery Balancing Module
Two-
Plane Balancing Procedure Overview
4A - Perform the Trial Run on Plane 1
Spin
-
With the trial weight securely attached, start the machine again, and perform a
trial run on plane 1. The trial run calibrates the machine's unbalance and allows the
Microlog to calculate the influence coefficient and permanent correction weight amount
and placement.
To allow for accurate balancing computations, the trial weight should pass the 30/30
rule. The trial weight should:
•
A - Increase or decrease the 1X vibration amplitude by at least 30%, or
•
B - Change the phase angle by at least 30 degrees, or
•
C - A combination of A and B.
4B - Perform the Trial Run on Plane 2
Spin
–
With the trial weight on Plane 1, perform a trial run on Plane 2.
When us
ing two sensors, all Plane 1 and 2 runs occur
simultaneously. Performing separate runs is only necessary if a
single sensor needs to be moved between the planes.
5 – Attach the Trial Weight to Plane 2
Stop
– Stop the machine, remove the trial weight from Plane 1 and attach it to Plane 2.
6A – Perform Trial Run on Plane 1
Spin
-
With the trial weight on Plane 2, perform a Trial Run on Plane 1.
6B – Perform Trial Run on Plane 2
Spin
-
With the trial weight on Plane 2, perform a Trial Run on Plane 2.
7 - Attach the Permanent Correction Weights
Stop
- Stop the machine, remove the trial weight from Plane 2, then attach the
specified correction weights at the specified angles on each balance plane (1 and 2).
8A - Perform a Correction Weight Run on Plane 1
Spin
-
Start the machine again, and perform a Correction Weight Run on Plane 1.
The correction weight run performs two functions:
•
It calculates the amount of residual imbalance with the correction weights in place
to confirm that the plane is now balanced within tolerances.
•
If further balancing is necessary, it automatically applies the influence coefficient to
calculate an additional “trim” weight that can be added to further balance the plane.
8B - Perform a Correction Weight Run on Plane 2
Spin
- Perform a Correction Run on Plane 2.
SKF Microlog - GX Series