Run Up / Coast Down Module
How to Set Up a RUCD Measurement
RUCD LED Indicators
In RUCD mode:
•
The Microlog’s red LED indicates an overload error (clipping, or any streaming
error) is occurring during data acquisition.
•
The amber LED indicates that an error has occurred during data acq
uisition
(although the error condition may have disappeared again).
•
The green LED indicates no errors occurred during data acquisition.
RUCD Setup Fields
Figure 7 - 3.
A RUCD Setup Screen.
•
Enter appropriate setup information in the following fields:
Channels
– (
CH1
,
CH1 & CH2
, or
CH1 & CH2 & CH3
), Specify the input channel(s) for
the RUCD measurement.
Sensor –
Select the appropriate preconfigured sensor from the setup screen’s context
sensitive sensor list. Note that the specified sensor type determines available options
and engineering units for subsequent setup fields.
The
Variable
sensor option allows you to configure settings for a
sensor that is not on the sensor list.
Sensor Units –
(Not editable if a preconfigured sensor is selected in the
Sensor
field.)
When the
Variable
sensor is selected, select the measurement units to use for the type
of sensor being used. Opt
ions include
g, in/s, mil, V, psi, lbf, A,
and
mil
.
Sensitivity –
(Not editable if a preconfigured sensor is selected in the
Sensor
field.)
When the
Variable
sensor is selected, use the alphanumeric keypad to enter transducer
sensitivity in millivolts (mV) per Engineering Unit (EU).
7 - 4