Order No. 6SL3210-5FE...
10-4UA0 10- 8UA0 11-0UA0 11-5UA0 12- 0UA0 13-5UA0 15-0UA0 17-0UA0
Frame size
FSAA
FSA
FSA
FSB
FSB
FSC
FSC
FSC
Permissible supply configu-
ration
TN, TT, IT
Short-circuit current (SCCR) Maximum permissiIble short-circuit current: 65 kA rms
Minimum required short-circuit current: 5 kA rms
Rated input current (A)
1.5
2.6
3.8
6.6
9.8
13.8
15.8
16.5
Power supply capacity (kVA) 1.7
3.0
4.3
7.6
11.1
15.7
18.0
18.9
Inrush current (A)
8.0
8.0
8.0
4.0
4.0
2.5
2.5
2.5
24 VDC power supply
Voltage (V)
24 (-15% to +20%)
2)
Maximum current (A)
When using a motor without a brake: 1.6 A
When using a motor with a brake: 1.6 A + motor holding brake rated current (See Section
Technical data - servo motors (Page 73)".)
Ripple caused by the rectifier
≤ 5%
Safety insulation class
PELV
1)
The values here are calculated at rated load.
2)
When SINAMICS V90 works with a motor with a brake, the voltage tolerance of 24 VDC power supply must be -10% to