Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
350
Operating Instructions, 04/2019, A5E36037884-007
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p1663
Current setpoint filter 2
denominator natural fre-
quency
0.5
16000.0
1000.0 Hz Float
IM
T, U
Description: Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1664
Current setpoint filter 2
denominator damping
0.001
10.000
0.300
-
Float
IM
T, U
Description: Sets the denominator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1665
Current setpoint filter 2
numerator natural fre-
quency
0.5
16000.0
1000.0 Hz Float
IM
T, U
Description: Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1666
Current setpoint filter 2
numerator damping
0.000
10.000
0.010
-
Float
IM
T, U
Description: Sets the numerator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1668
Current setpoint filter 3
denominator natural fre-
quency
0.5
16000.0
1000.0 Hz Float
IM
T, U
Description: Sets the denominator natural frequency for current setpoint filter 3 (PT2, general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1669
Current setpoint filter 3
denominator damping
0.001
10.000
0.300
-
Float
IM
T, U
Description: Sets the denominator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1670
Current setpoint filter 3
numerator natural fre-
quency
0.5
16000.0
1000.0 Hz Float
IM
T, U
Description: Sets the numerator natural frequency for current setpoint filter 3 (general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1671
Current setpoint filter 3
numerator damping
0.000
10.000
0.010
-
Float
IM
T, U
Description: Sets the numerator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1673
Current setpoint filter 4
denominator natural fre-
quency
0.5
16000.0
1000.0 Hz Float
IM
T, U
Description: Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1674
Current setpoint filter 4
denominator damping
0.001
10.000
0.300
-
Float
IM
T, U
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.