General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
66
Operating Instructions, 04/2019, A5E36037884-007
Parameter
Description
Vibration
Operation
Shock
Operational area II
Peak acceleration: 5 g, 30 ms and 15 g, 11 ms
Quantity of shocks: 3 per direction × 6 directions
Duration of shock: 1 s
Vibration
Operational area II
10 Hz to 58 Hz: 0.075 mm deflection
58 Hz to 200 Hz: 1 g vibration
Product packag-
ing
Vibration
2 Hz to 9 Hz: 3.5 mm deflection
9 Hz to 200 Hz: 1 g vibration
Quantity of cycles: 10 per axis
Sweep seed: 1 octave/min
1)
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be
provided in accordance with the National Electrical Code and any additional local codes.
2)
The V90 200 V servo drive has an overvoltage threshold of 410 V DC and an undervoltage threshold of 150 V DC; the
V90 400 V servo drive has an overvoltage threshold of 820 V DC and an undervoltage threshold of 320 V DC.
3)
SINAMICS V90 does not support motor overtemperature protection. Motor overtemperature is calculated by I
2
t and
protected by the output current from the drive.
Specific technical data
Order No. 6SL3210-5FE...
10-4UA0 10- 8UA0 11-0UA0 11-5UA0 12- 0UA0 13-5UA0 15-0UA0 17-0UA0
Frame size
FSAA
FSA
FSA
FSB
FSB
FSC
FSC
FSC
Rated output current (A)
1.2
2.1
3.0
5.3
7.8
11.0
12.6
13.2
Max. output current (A)
3.6
6.3
9.0
13.8
23.4
33.0
37.8
39.6
Max. supported motor power
(kW)
0.4
0.75
1.0
1.75
2.5
3.5
5.0
7.0
Output frequency (Hz)
0 to 330
Cooling method
Self-cooled
Fan-cooled
Outline dimensions (W x H x
D, mm)
60 x 180
x 200
80 x 180 x 200
100 x 180 x 220
140 x 260 x 240
Weight (kg)
1.800
2.500
2.510
3.055
3.130
6.515
6.615
6.615
Power loss
1)
Main circuit (W)
12
29
32
84
96
92
115
138
Regenerative resistor (W)
17
57
57
131
131
339
339
339
Control circuit (W)
32
32
35
35
35
36
36
36
Total (W)
61
118
124
250
262
467
490
513
Power supply
Voltage/frequency
3-phase 380 VAC to 480 VAC, 50/60 Hz
Permissible voltage fluctua-
tion
-15% to +10%
Permissible frequency fluc-
tuation
-10% to +10%