Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
381
Par. No.
Name
Unit
Data type
r29942
DO signals status indicating
-
U32
Description: Indicates the status of DO signals.
•
Bit 0: RDY
•
Bit 1: FAULT
•
Bit 2: INP
•
Bit 3: ZSP
•
Bit 4: SPDR
•
Bit 5: TLR
•
Bit 6: SPLR
•
Bit 7: MBR
•
Bit 8: OLL
•
Bit 9: WARNING1
•
Bit 10: WARNING2
•
Bit 11: REFOK
•
Bit 12: CM_STA
•
Bit 13: RDY_ON
•
Bit 14: STO_EP
r29979
Index of actual electronic gear
-
U32
Description: Displays the status of position loop.
•
Bit 0 to Bit 1: Actual EGear index