Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
373
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p29341
Warning 2 assigned for
digital output
1
6
2
-
U16
IM
T
Description: Defines conditions for WARNING2.
•
1: Motor overload protection warning: 85% of overload threshold has been reached.
•
2: Holding brake power overload warning: threshold p29005 has been reached.
•
3: Fan warning: life time of fan expired (40000 hours), replacement of fan needed.
•
4: Encoder warning
•
5: Motor overtemperature warning: 85% of overtemperature threshold has been reached.
•
6: Capacitor service life warning: The capacitor has reached its expiry, so replace it.
p29350
Select sources for analog
output 1
0
12
0
-
U16
IM
T
Description: Selects signal source for analog output 1.
•
0: Actual speed (reference p29060)
•
1: Actual torque (reference 3 × r0333)
•
2: Speed setpoint (reference p29060)
•
3: Torque setpoint (reference 3 × r0333)
•
4: DC bus voltage (reference 1000 V)
•
5: Pulse input frequency (reference 1k)
•
6: Pulse input frequency (reference 10k)
•
7: Pulse input frequency (reference 100k)
•
8: Pulse input frequency (reference 1000k)
•
9: Remaining number of pulses (reference 1k)
•
10: Remaining number of pulses (reference 10k)
•
11: Remaining number of pulses (reference 100k)
•
12: Remaining number of pulses (reference 1000k)
p29351
Select signal source for
analog 2
0
12
1
-
U16
IM
T
Description: Selects signals for analog output 2.
•
0: Actual speed (reference p29060)
•
1: Actual torque (reference 3 × r0333)
•
2: Speed setpoint (reference p29060)
•
3: Torque setpoint (reference 3 × r0333)
•
4: DC bus voltage (reference 1000 V)
•
5: Pulse input frequency (reference 1k)
•
6: Pulse input frequency (reference 10k)
•
7: Pulse input frequency (reference 100k)
•
8: Pulse input frequency (reference 1000k)
•
9: Remaining number of pulses (reference 1k)
•
10: Remaining number of pulses (reference 10k)
•
11: Remaining number of pulses (reference 100k)
•
12: Remaining number of pulses (reference 1000k)