Connecting
4.3 Control/status interface - X8
SINAMICS V90, SIMOTICS S-1FL6
122
Operating Instructions, 04/2019, A5E36037884-007
4.3.1
Digital inputs/outputs (DIs/DOs)
SINAMICS V90 supports free assignment of signals to the following digital input and output
terminals depending on the control mode selected:
DI1 to DI8 -- Assignable with parameters p29301 to p29308
DO1 to DO6 -- Assignable with parameters p29330 to p29335
Exception: DI9 and DI10
DI9 is permanently assigned with the signal EMGS (quick stop) and DI10 is permanently
assigned with the signal C-MODE (change mode).
For detailed information about default DI/DO signal assignments, see the table below:
Pin No.
Digital in-
puts/outputs
Parameters
Default signals/values
Index 0 (PTI) Index 1 (IPos) Index 2 (S)
Index 3 (T)
Index 9
(Fast PTI)
5
DI1
p29301
1 (SON)
1 (SON)
1 (SON)
1 (SON)
1 (SON)
6
DI2
p29302
2 (RESET)
2 (RESET)
2 (RESET)
2 (RESET)
2 (RESET)
7
DI3
p29303
3 (CWL)
3 (CWL)
3 (CWL)
3 (CWL)
8
(EGEAR1)
8
DI4
p29304
4 (CCWL)
4 (CCWL)
4 (CCWL)
4 (CCWL)
9
(EGEAR2)
9
DI5
p29305
5 (G-
CHANGE)
5 (G-
CHANGE)
12 (CWE)
12 (CWE)
5 (G-
CHANGE)
10
DI6
p29306
6 (P-TRG)
6 (P-TRG)
13 (CCWE)
13 (CCWE) 19 (SLIM1)
11
DI7
p29307
7 (CLR)
21 (POS1)
15 (SPD1)
18 (TSET)
7 (CLR)
12
DI8
p29308
10 (TLIM1)
22 (POS2)
16 (SPD2)
19 (SLIM1)
10 (TLM1)
30
DO1
p29330
1 (RDY)
31
DO2
p29331
2 (FAULT)
32
DO3
p29332
3 (INP)
29/33
DO4
p29333
5 (SPDR)
34/44
DO5
p29334
6 (TLR)
35/49
DO6
p29335
8 (MBR)
Note
The selected DI signal will respond with a delay time of 8 ms to 16 ms.
Note
DO signal inverse
The logics of digital output signals DO1 to DO6 can be inversed. You can inverse the logics
of DO1 to DO6 by setting the bit 0 to bit 5 of parameter p0748.