Connecting
4.3 Control/status interface - X8
SINAMICS V90, SIMOTICS S-1FL6
124
Operating Instructions, 04/2019, A5E36037884-007
No.
Name
Type
Description
Control mode
PTI
IPos
S
T
Fast
PTI
8
EGEAR1 Level Electronic gear.
A combination of the signals EGEAR1 and
EGEAR2 can select four electronic gear ratios.
EGEAR2 : EGEAR1
•
0 : 0: electronic gear ratios 1
•
0 : 1: electronic gear ratios 2
•
1 : 0: electronic gear ratios 3
•
1 : 1: electronic gear ratios 4
✓
X
X
X
✓
9
EGEAR2 Level
✓
X
X
X
✓
10
TLIM1
Level Torque limit selection.
A combination of TLIM1 and TLIM2 can select
four torque limit sources (one external torque
limit, three internal torque limits).
TLIM2 : TLIM1
•
0 : 0: internal torque limit 1
•
0 : 1: external torque limit (analog input 2)
•
1 : 0: internal torque limit 2
•
1 : 1: internal torque limit 3
✓
✓
✓
X
✓
11
TLIM2
Level
12
CWE
Level Enable clockwise rotations.
•
1: Enable clockwise rotation, ramp up
•
0: Disable clockwise rotation, ramp down
X
X
✓
✓
X
13
CCWE
Level Enable counter-clockwise rotations.
•
1: Enable counter-clockwise rotation, ramp
down
•
0: Disable counter-clockwise rotation, ramp
up
X
X
✓
✓
X
14 ZSCLAM
P
Level Zero speed clamps.
•
1 = when the motor speed setpoint is an
analog signal and lower than the threshold
level (p29075), the motor is clamped.
•
0 = no action
X
X
✓
X
X