General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
64
Operating Instructions, 04/2019, A5E36037884-007
Order No. 6SL3210-5FB...
10-1UA2
10-2UA2
10-4UA1
10-8UA0
11-0UA1
11-5UA0
12-0UA0
Frame size
FSA
FSA
FSB
FSC
FSD
FSD
FSD
capacity (kVA)
3-phase 0.5
0.7
1.1
1.9
2.7
4.2
4.6
Inrush current (A)
8.0
24 VDC power supply
Voltage (V)
24 (-15% to +20%)
2)
Maximum current (A)
When using a motor without a brake: 1.6 A
When using a motor with a brake: 1.6 A + motor holding brake rated current (See Section
"Technical data - servo motors (Page 68)".)
Ripple caused by the rectifier
≤ 5%
Safety insulation class
PELV
1)
The values here are calculated at rated load.
2)
When SINAMICS V90 works with a motor with a brake, the voltage tolerance of 24 VDC power supply must be -10% to
+10% to meet the voltage requirement of the brake.
2.7.1.2
SINAMICS V90 400 V variant
General technical data
Parameter
Description
Overload capability
300%
Control system
Servo control
Dynamic brake
Built-in
Protective functions
Earthing fault protection, output short-circuit protection
1)
, overvoltage/undervoltage
protection
2)
, drive I
2
t protection, motor overtemperature protection, IGBT overtemper-
ature protection
3)
Overvoltage criteria
Category III
Certification
Speed control mode
Speed control range
Analog speed command 1:2000, internal speed command 1:5000
Analog speed command input
-10 V DC to +10 V DC/rated speed