Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
370
Operating Instructions, 04/2019, A5E36037884-007
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p29302[0..
.9]
Digital input 2 assignment 0
28
2
-
I16
IM
T
Description: Defines the function of digital input signal DI2
Index:
•
[0]: DI2 for the control mode 0
•
[1]: DI2 for the control mode 1
•
[2]: DI2 for the control mode 2
•
[3]: DI2
for the control mode 3
•
[4...8]: Reserved
•
[9]: DI2 for the control mode 9
p29303[0..
.9]
Digital input 3 assignment 0
28
[0...3] 3;
[9] 8
-
I16
IM
T
Description: Defines the function of digital input signal DI3
Index:
•
[0]: DI3 for the control mode 0
•
[1]
: DI3 for the control mode 1
•
[2]: DI3 for the control mode 2
•
[3]: DI3 for the control mode 3
•
[4...8]: Reserved
•
[9]: DI3 for the control mode 9
p29304[0..
.9]
Digital input 4 assignment 0
28
[0...3] 4;
[9] 9
-
I16
IM
T
Description: Defines the function of digital input signal DI4
Index:
•
[0]: DI4 for the control mode 0
•
[1]: DI4 for the control mode 1
•
[2]: DI4 for the control mode 2
•
[3]: DI4 for the control mode 3
•
[4...8]: Reserved
•
[9]: DI4 for the control mode 9
p29305[0..
.9]
Digital input 5 assignment 0
28
[0...1] 5;
[2...3]
12; [9] 5
-
I16
IM
T
Description: Defines the function of digital input signal DI5
Index:
•
[0]: DI5 for the control mode 0
•
[1]: DI5 for the control mode 1
•
[2]: DI5 for the control mode 2
•
[3]: DI5 for the control mode 3
•
[4...8]: Re
served
•