4-29
Group 10: Speed Feedback Parameter
Parameters
Functions
Settings
Factory
Setting
Customer
10-00
PG (encoder) Pulses
1~20000
600
10-01
Encoder Input Setting
(channel 1)
0: Phase A leads in a forward run
command and phase B leads
in a reverse run command.
(rising/falling edge trigger)
(Pulses x 4)
1: Phase B leads in a forward run
command and phase A leads
in a reverse run command.
(rising/falling edge trigger)
(Pulses x 4)
2: Phase A is a pulse input and
phase B is a direction input.
(low input = reverse direction,
high input = forward direction)
3: Phase A is a pulse input and
phase B is a direction input.
(low input = forward direction,
high input = reverse direction)
4: Phase A is a forward run pulse,
then phase B is High.
Phase B is a reverse run pulse,
then phase A is High.
5: Phase B is a forward run pulse,
then phase A is High.
Phase A is a reverse run pulse,
then phase B is High.
6: Phase A leads in a forward run
command and phase B leads
in a reverse run command.
(level trigger)
7: Phase B leads in a forward run
command and phase A leads
in a reverse run command.
(level trigger)
0
10-02
PG Feedback Fault
Treatment
0: warn and keep operating
1: warn and RAMP to stop
2: warn and COAST to stop
0
10-03
PG Feedback Fault
Detection Time
0.00~10.00 s
0.10
10-04
PG Feedback Filter
Time
0.001~1.000 s
0.010
10-05
PG Slip Range
0.0~50.0%
10.0