TIME
Frequency
01-28
Skip Frequency 1 (upper limit)
Factory setting
0.00
01-29
Skip Frequency 1 (lower limit)
Factory setting
0.00
01-30
Skip Frequency 2 (upper limit)
Factory setting
0.00
01-31
Skip Frequency 2 (lower limit)
Factory setting
0.00
01-32
Skip Frequency 3 (upper limit)
Factory setting
0.00
01-33
Skip Frequency 3 (lower limit)
Factory setting
0.00
Settings
0.00~400.00Hz
1
These parameters determine the skip frequencies of the AC drive.
1
Please use the following hierarchy when setting these parameters: Pr. 01-28 > Pr. 01-29 >
Pr. 01-30 > Pr. 01-31> Pr. 01-32 > Pr. 01-33. The Skip frequency will be disabled if this
rule is not followed.
1
The Skip Frequencies are useful when a motor has vibration at a specific frequency