5-80
10-32
REV Limit of Absolute P2P
Factory setting
0
Settings
0: No Limit
1~60000
1
10-31 and 10-32 are protective parameters. When the settings of 02-01~02-06 /
02-23~02-30 are set to d42 P2P FWD Limit/d 43 REV Limit and it is ON, AC drive will free
stop when it is over the limit.
10-33
P2P Command 0
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-34
P2P Command 1
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-35
P2P Command 2
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-36
P2P Command 3
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-37
P2P Command 4
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-38
P2P Command 5
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-40
P2P Command 7
Factory setting
0
Settings
0~50000 (in position control 2 mode)
10-41
P2P Pulse
Factory setting
1
Settings
1~20000 (*4 for 10-00)
10-42
P2P mm
Factory setting
1
Settings
1~20000
1
The distance that each pulse moves (mm) should use with 10-33~10-40 (8-point P2P
command) for application.