4-6
Parameters
Functions
Settings
Factory
Setting
Customer
00-12
Constant Torque
Operation Selection
0: OL (100%) constant torque
operation
1: OL (125%) variable torque
operation
00-13
Optimal Acceleration
/Deceleration Setting
0: Linear acceleration/deceleration
1: Auto acceleration, linear
deceleration
2: Linear acceleration, auto
deceleration
3: Auto acceleration/deceleration
4: Linear acceleration/deceleration,
but conduct the stall prevention
throughout the auto
acceleration/deceleration
function.
0
00-14
Time Unit for
Acceleration
/Deceleration and S
Curve
0: unit: 0.01 s
1: unit: 0.1 s
0
00-15
Carrier Frequency
Upper Bound
0: soft pwm
1~15kHz
15
00-16
Carrier Frequency
Lower Bound
1-15kHz (disabled during soft
PWM)
10
00-17
Center Frequency of
Soft pwm
1~7kHz
3
00-18
Auto Voltage
Regulation (AVR)
Function
0: AVR function enabled
1: AVR function disabled
2: AVR function disabled during
deceleration
0
00-19
Automatic
Energy-Saving
Operation
BIT0=0: Disable automatic
energy-saving operation
BIT0=1: Enable automatic
energy-saving operation
BIT1=0: Maximum output voltage
equals to the input power voltage
BIT1=1: Maximum output voltage
could be greater than the input
power voltage (over-modulation
available)
00010