4-23
Parameters
Functions
Settings
Factory
Setting
Customer
06-09
Over-Torque Detection
Selection 2 (OL3)
0: Disable
1: over-torque detection
during constant speed
operation, continue to
operate after detection
2: over-torque detection
during constant speed
operation, stop operation
after detection.
3: over-torque detection
during operation, continue
operation after detection.
4: over-torque detection
during operation, stop
operation after detection.
0
06-10
Over-Torque Detection
Level 2 (OL3)
10~250%
150
06-11
Over-Torque Detection
Time 2 (OL3)
0.0~60.0 s
0.1
06-12
Over-Torque
limit
0
250%
150
06-13
Electronic Thermal Relay
Selection (I
2
t)
0: Inverter/vector motor
1: Standard motor
2: Electronic thermal relay
function disabled
2
06-14
Electronic Thermal Relay
Time (I
2
t)
30~600 s
60
06-15
Heat Sink Over-Heat (oH)
Warning
0.0~110.0
85.0
06-16
Op stall low limit
0~250%
120
*