5-24
Settings
Functions
Explanations
20
PCO completed
21
Pre-set counter value attained
Please refer to 02-16
22
Desired counter value attained
Please refer to 02-17
23
Heat sink overheat warning
Please refer to 06-15
24
Operation frequency attained 1 1both
directions)
25
Operation frequency attained 2 1both
directions)
26
Pre-set frequency attained 1 1both
directions)
27
Pre-set frequency attained 2 1forward
only)
28
Pre-set frequency attained 1 1both
directions)
29
Pre-set frequency attained 2 1forward
only)
30
Software braking output
Please refer to 07-00
31
Position Achieved
In position mode, position point can
output a position achieved signal by
setting this parameter. At this moment,
AC drive achieves position and motor is
in holding state.
32~47 PCO Step Indication
Corresponds to the 0~15 step speeds
48~63 Multi-step Indication
Corresponds to the 0~15 step speeds
64
PG Fault
65
PG Stall
69
Over-torque1oL3)
Please refer to 06-09
70
Zero speed 1STOP)
71
Position synchronization 1 (10-10)
72
Position synchronization 2 (10-23)
In position mode, you can output a
position synchronization signal by
setting d71, d72 (please refer to 10-10,
10-23)
02-15
Multi-Function Output Direction
Factory setting 0
Settings
0~15 11 high)